BS PD CEN/TS 17434:2020
Ambient air. Determination of the particle number size distribution of atmospheric aerosol using a Mobility Particle Size Spectrometer (MPSS)
This document describes a standard method for determining particle number size distributions inambient air in the size range from 10 nm to 800 nm at total concentrations up to approximately105 cm-3 with a time resolution of a few minutes. The standard method is based on a Mobility ParticleSize Spectrometer (MPSS) used with a bipolar diffusion charger and a Condensation Particle Counter(CPC) as the detector. The document describes the performance characteristics and minimumrequirements of the instruments and equipment to be used, and describes sampling, operation, dataprocessing and QA/QC procedures, including calibration.
Cross References: ISO 27891:2015 CEN/TS 16976:2016 ISO 15900 ISO 3696:1987 ISO/IEC GUIDE 98-3:2008 Ed 1
All current amendments available at time of purchase are included with the purchase of this document.
Product Details
Published: 04/14/2020 ISBN(s): 9780539017731 Number of Pages: 66 File Size: 1 file , 1.2 MB Product Code(s): 30380868, 30380868, 30380868